Recommended Operating Conditions
Parameter
Min
Typ
Max
Unit
Supply Input Voltage
+9
+12
+13
V
LiPo Battery Input Voltage
+3
+3.3-3.7
+4.4
V
Buck Converter Supply Voltage
+5
+5.1
+5.2
V
Buck Converter Supply Current
2.8
A
Boost Converter Supply Voltage
+2.7
+5.15
+5.2
V
Boost Converter Supply Current
1.8
A
Operating Temperature
-20
35
60
°C